5/30
Kategorie
1 Waste-to-Energy 2 MBA 3 Sortieranlagen 3.1 Gemischte Wertstoffe 3.2 Verpackungen 3.3 Plastik 3.4 Metall 3.5 Papier 3.6 Glas 3.7 Sperrmüll 3.8 Batterien 3.9 Elektro 3.10 Bau- und Abbruch 3.11 Sonstige Sortieranlagen 4 Recyclinganlagen 4.1 Plastik, werkstofflich 4.2 Plastik, chemisch 4.3 Papier 4.4 Sonstige Recyclinganlagen 5 Biomass-to-Power 6 Biogas 7 Gefährliche Abfälle

Plant

Name
Köln
Country
Germany
Type
Waste to Energy
Province/Region
North Rhine-Westphalia
Status
active
Investments
n/a
Start of operation
1998
Heat use category
unknown
Input, capacity [t/a]
785.000
Input real
n/a
Input real (year of data)
n/a
Power generation capacity [MW]
46.7
Heat production capacity [MW]
26.7
Gross heat production [MW]
n/a
Average heating value [kJ/kg]
10.086
Fuel category
MSW
Size category
>20
Remarks: As of 03/2021, Hitachi Zosen Inova Kraftwerkstechnik GmbH has replaced superheaters 5 and 6. In 2013, maintenance works on all four units caused several downtimes but waste throughput decreased only slightly. In 03/2012, AVG Köln applied for the approval to burn waste from foreign countries as an option for the future.

 

Unit 1

Status
active
Start of operation
1997
End of operation
n/a
Year of awarding
n/a
Input tons per hour
25
Unit fuel
MSW
Fuel category
MSW
Technology
Roller Grate
Main steam production at t/h at bar/°C
66,9 / 40 / 400
Flue gas cleaning technology (FGCT)
HCl-Washer / SO2-Washer / Fabric Filter / CAT
FGCT provider
DBA, LCS, ABB
Technology provider
DBA / Fisia Babcock
Type of thermal process
Grate
Power generation technology (PGT)
n/a
PGT provider
n/a
PGT category
unknown
Gross heat production [MW]
n/a
Heat production capacity [MW]
n/a
Power generation capacity [MW]
n/a
 
 

Unit 2

Status
active
Start of operation
1997
End of operation
n/a
Year of awarding
n/a
Input tons per hour
25
Unit fuel
MSW
Fuel category
MSW
Technology
Roller Grate
Main steam production at t/h at bar/°C
66,9 / 40 / 400
Flue gas cleaning technology (FGCT)
HCl-Washer / SO2-Washer / Fabric Filter / CAT
FGCT provider
DBA, LCS, ABB
Technology provider
DBA / Fisia Babcock
Type of thermal process
Grate
Power generation technology (PGT)
n/a
PGT provider
n/a
PGT category
unknown
Gross heat production [MW]
n/a
Heat production capacity [MW]
n/a
Power generation capacity [MW]
n/a
 
 

Unit 3

Status
active
Start of operation
1997
End of operation
n/a
Year of awarding
n/a
Input tons per hour
25
Unit fuel
MSW
Fuel category
MSW
Technology
Roller Grate
Main steam production at t/h at bar/°C
66,9 / 40 / 400
Flue gas cleaning technology (FGCT)
HCl-Washer / SO2-Washer / Fabric Filter / CAT
FGCT provider
DBA, LCS, ABB
Technology provider
DBA / Fisia Babcock
Type of thermal process
Grate
Power generation technology (PGT)
n/a
PGT provider
n/a
PGT category
unknown
Gross heat production [MW]
n/a
Heat production capacity [MW]
n/a
Power generation capacity [MW]
n/a
 
 

Unit 4

Status
active
Start of operation
1997
End of operation
n/a
Year of awarding
n/a
Input tons per hour
25
Unit fuel
MSW
Fuel category
MSW
Technology
Roller Grate
Main steam production at t/h at bar/°C
66,9 / 40 / 400
Flue gas cleaning technology (FGCT)
HCl-Washer / SO2-Washer / Fabric Filter / CAT
FGCT provider
DBA, LCS, ABB
Technology provider
DBA / Fisia Babcock
Type of thermal process
Grate
Power generation technology (PGT)
n/a
PGT provider
n/a
PGT category
unknown
Gross heat production [MW]
n/a
Heat production capacity [MW]
n/a
Power generation capacity [MW]
n/a
 
 

Operator

AVG Abfallentsorgungs- und Verwertungsgesellschaft Köln mbH (AVG Köln)
Geestemünder Straße 23
50735 Köln
0049-221/7170-154
info@avgkoeln.de
Suche
Country


Downloads

WtE Project Tracker

WtE, List Of Active Plants

What you see is a trial version of ecoprog's waste & bio data.

Data sets in this section
in trial version: 30
in full version: 4027